American Standard Furnace - Troubleshooting Guide - HVAC BOSS (2024)

American Standard offers furnaces in three tiers – Silver, Gold, and Platinum. No matter what kind of unit you decide to go for, you might find yourself, at one point, searching for ‘American Standard furnace troubleshooting’.

When your furnace is not heating, power source issues, a faulty thermostat, a dirty filter, and outside blockages might be to blame. The furnace can also start to blow cold air; in such a case, check the blower motor, the fan settings, the drain line, and the filters.

You can dive into the issue a bit deeper before calling a professional. The chances are high that you’ll be able to take care of the problem yourself.

Top Reasons Why Your American Standard Furnace Isn’t Heating

A Power Source Issue

What it is: even though American Standard furnaces run mainly on gas or oil, they still need electricity in order to function.

The unit is able to produce heat inside the combustion chamber, but without the blower fan motor (that requires electricity) the heat won’t go anywhere.

Moreover, a lot of modern furnaces come with an electronic ignition system, so the burners simply won’t light, in case there is a power outage.

How it fails: power supply problems can be caused by a variety of different sources. For example, weather conditions, distribution network faults, and so on.

How to fix: check the circuit breakers that power the unit. If they are tripped, fix the issue.

Also, make sure that the power switch is in the ‘on’ position. If you have just turned it on, don’t forget to wait for at least a few minutes as the furnace can start working with a slight delay.

An Issue with the Thermostat

American Standard Furnace - Troubleshooting Guide - HVAC BOSS (1)

What it is: the thermostat is the main control point of your heating system. This temperature-sensitive switch, basically, determines how much heat is going to be delivered by your furnace and when.

How it fails: the most common reason for a faulty thermostat is dead batteries. Sometimes, there might also be an issue with the wires – they are either not firmly connected, or they have degraded over time.

How to fix: you might simply have to change the batteries, especially, if you haven’t done that in quite a while.

Have a Question? Ask HVAC Technician

Click here to use the chatbox to speak with one of our technicians.
No in-home service calls. No appointments.

Also, do make sure that the thermostat is set right. Once you have verified that the device is set to ‘heating’, increase the temperature, and see if anything happens.

Tip: in order for the thermostat to work, the room temperature has to be lower than the device’s set temperature.

Related: Honeywell Thermostat Not Reaching Set Temperature?

A Clogged Filter

American Standard Furnace - Troubleshooting Guide - HVAC BOSS (2)

What it is: a lot of homeowners think that the air filter filters out the air in their house and, consequently, increases its quality.

In a way, that is right. But the main job of your furnace’s air filter is to protect the blower fan from dust, hair, and debris.

Fact: your filter has a MERV rating. The higher the rating – the more particles the filter will be able to remove from the air.

How it fails: naturally, the filter will get dirty or even clogged over time. As a result, it will start blocking the airflow.

A clogged filter will make the system work even harder causing it to wear out faster than it is supposed to. This also leads to higher energy bills.

How to fix: simply change your filter regularly. The exact schedule would depend on the thickness of the filter that you use, whether or not you have pets, and on the overall cleanliness of your house.

Usually, you would have to change the filter once every 1-3 months, if you tend to use the furnace on a regular basis.

Tip: do make sure that you have installed the filter correctly. If you have put the thing in the other way round, it will fail to work.

Related: Cheap Vs. Expensive Furnace Filters

Blockages

What it is: usually, a house has supply ducts through which the heated air gets into the rooms. The system also has exterior furnace vents – this is from where the combustion gases escape the system.

How it fails: all the openings mentioned above need enough space around them, in order to function properly. At times, they can get blocked.

For example, homeowners might find snow and nests inside or close to their furnace vents.

By the way, the actual furnace also needs to have enough space around it.

If there is a blockage, the unit might get too hot. Moreover, it becomes more challenging for a technician to get close to the furnace, if there isn’t enough free space around the unit.

How to fix: proper venting is crucial for your safety. Without it, the system won’t be able to work the way it’s supposed to.

Always check the exterior vents and the supply ducts to make sure that they are not blocked.

Tip: in general, experts recommend leaving 30 inches around the furnace on all sides to ensure proper functioning.

Reasons Why Your American Standard Furnace Is Blowing Cold Air

Blower Motor

American Standard Furnace - Troubleshooting Guide - HVAC BOSS (3)

What it is: the blower motor is the part of your furnace that pushes the heated air through the vents in your house.

If the thing is not working, then your home is going to stay cold as the heated air gets lost in the system.

How it fails: the blower motor or its parts can simply wear out over time. Excessive moisture, overheating, and dust buildup might also be to blame.

How to fix: check if the power is reaching the motor with the help of a multimeter.

In case the motor is running, but the air is not moving – check the connecting belt (fan belt). You might need to replace the belt, instead of getting a whole new blower motor.

Related: Why Furnace Is Not Blowing Hot Air?

The Fan Is Set to ‘On’

What it is: if your fan is blowing hot air only some times and cold air – the rest of the time, then this might be because you have your fan set to ‘on’.

How it fails: this is not a failure, it’s just a special mode that your furnace has.

The fan controls the blower and if the thing is set to ‘on’, the fan will be making the blower work 24/7. And your furnace is not heating the air all the time, right?

This means that, at some point, the blower will be pushing unheated air into the rooms.

How to fix: simply set the fan to ‘auto’. This will make the fan work only once the furnace is on.

The Furnace Is Tripping the Limit Switch

What it is: the limit switch is a component that, basically, safeguards the whole system.

It tells the blower fan when to turn on and it detects the supply air temperature.

How it fails: if the component ‘thinks’ that the temperature of the supply air is too hot, it will trip.

This is done to ensure that the whole system does not overheat. The limit switch will make the unit shut down until it cools.

How to fix: surprisingly, the problem might be with your air filters.

Clogged filters block airflow over the heat exchanger. This means that this component is going to overheat which, in its turn, causes the limit switch to trip.

Related: Why Is My Furnace Beeping?

Drain Line Blockage

American Standard Furnace - Troubleshooting Guide - HVAC BOSS (4)

What it is: this might be your cause, if you happen to have a high-efficiency American Standard furnace.

These units create water that is then pushed out of the system through a drain line.

How it fails: the drain line might get blocked. In such a case, the water is going to return into the furnace and this will cause the overflow kill switch to shut the furnace down.

How to fix: if you have a broken condensate pump, then leave the job to a professional.

However, dust, mold, dirt, and ice can also cause such a problem.

If there is an issue with ice, then you would have to wrap the drain line with heat tape. Otherwise, try unclogging the condensate line.

How to Relight the Pilot Light ?

If you’re a lucky owner of an American Standard furnace with a standing pilot, then you might have to reignite the light at one point.

  • Follow the small copper tubes that are attached to the control valve to locate the pilot light.
  • Turn off the gas control.
  • Turn the knob to the ‘pilot’ position.
  • Ignite the flame with a spark igniter (if there is one) or a simple lighter.
  • Hold the control knob for 10-20 seconds.
  • Turn the knob to the ‘on’ position.
American Standard Furnace - Troubleshooting Guide - HVAC BOSS (2024)

FAQs

How do I reset my HVAC control board? ›

Switch on Your Furnace

Once you switch off your furnace, wait for a few seconds, then turn it back on. Doing so gives your furnace's control board the time it needs to shut down and clear the errors the sensors detected. Remember to observe your furnace as it starts up.

How do I reset my American Standard HVAC? ›

All Thermostat Models
  1. MAKE SURE THAT THE HVAC SYSTEM IS IDLE BEFORE PROCEEDING!
  2. Locate the switch for your thermostat in the breaker box.
  3. Flip the switch to the OFF position for 20-30 seconds.
  4. Return the switch to the ON position.
  5. The reboot process will take several minutes to complete.
Apr 28, 2023

What does 2 blinks mean on my furnace? ›

2 Flash Code

If your furnace is flashing 2 times it likely means the furnace is blowing cold air. This is happening most likely because the furnace is unable to catch a flame.

What are the most common furnace problems? ›

We know you're cold, so we'll dive right in.
  • Furnace Problem #1: The Thermostat Isn't Set To Heat. ...
  • Furnace Problem #2: Furnace Isn't Receiving Power. ...
  • Furnace Problem #3: Furnace Is Making A Grinding Or Scraping Sound. ...
  • Furnace Problem #4: Furnace Is Making A Squealing Noise. ...
  • Furnace Problem #5: Pilot Light or Ignition Issues.

What is the most common furnace failure? ›

Dirty Filters

A very common cause of furnaces not working properly is dirty or clogged filters. This could be especially true if you have pets or a large number of people in your household.

How do I know if my HVAC control board is bad? ›

Use your voltage meter to determine if the line has power. If your board's wire receives a reading of 120 volts AC, then the power works fine. Power going into your board should light up the indicator light, but if it remains off, it's time to replace the board.

Where is reset button on HVAC unit? ›

Some air conditioning systems have a reset switch, which is a small, red button. Typically, the button will be on the outdoor unit.

Why won't my American Standard Heating & air conditioning turn on? ›

The air conditioner won't turn on.

Check the breaker or fuse box. A tripped breaker or blown fuse may have interrupted the power to the AC unit. Check your thermostat settings. The AC may be off at the thermostat, or you may not have turned the thermostat low enough to power on the AC.

Why is my American Standard not heating? ›

My system isn't heating

Solution: Check your home's thermostat to make sure it's turned on and set to the indoor temperature you desire. Try raising the temperature by a few degrees to see if you notice a difference. If not, try resetting your thermostat. Possible cause: Your circuit breaker malfunctioned.

Why is my American Standard not blowing heat? ›

Anytime you have furnace problems, your first step should be to check the thermostat. Ensure it is set higher than room temperature and set to “heat.” Turn the fan switch to on. If the fan doesn't turn on, it's possible the furnace isn't getting power, or the motor is broken. Change your filter.

Why is my HVAC blinking? ›

Inducers and pressure switches are parts of the furnace that make sure the furnace is venting unwanted gas. The blinking light could indicate that there is a blockage or other issue preventing these components to function as they should.

What does 3 blinks mean? ›

Battery LED flashes 3 times

Certain batteries will flash 3 times to indicate a short circuit. Most standard e-cig batteries will have what's called short circuit protection, so when there is a short and you press the fire button it will just blink 3 times and then won't do anything.

Why does my furnace status light blink 3 times? ›

Three Blinking Lights on a Furnace

Three blinks mean there is an issue with the pressure sensor switch. This can occur for various reasons, whether that's your exhaust vent is blocked by a bird's nest, a strong wind gusted in and messed up the sensors, or the sensor needs to be replaced.

Where are the reset buttons on a furnace? ›

First of all, be aware that not all furnaces have a reset button; however, most do. If your electric furnace has one, it's most likely located within the blower housing, next to the motor. If you own a gas furnace, it's probably located within the control panel.

Why is my American Standard electric furnace not heating? ›

Double check that your furnace is on. A good place to start is by checking the breaker in your electrical panel. If the breaker was tripped, check for loose connections before turning it back on. Also make sure that the furnace switch is turned on.

References

Top Articles
Latest Posts
Article information

Author: Jamar Nader

Last Updated:

Views: 6240

Rating: 4.4 / 5 (75 voted)

Reviews: 82% of readers found this page helpful

Author information

Name: Jamar Nader

Birthday: 1995-02-28

Address: Apt. 536 6162 Reichel Greens, Port Zackaryside, CT 22682-9804

Phone: +9958384818317

Job: IT Representative

Hobby: Scrapbooking, Hiking, Hunting, Kite flying, Blacksmithing, Video gaming, Foraging

Introduction: My name is Jamar Nader, I am a fine, shiny, colorful, bright, nice, perfect, curious person who loves writing and wants to share my knowledge and understanding with you.